	<url>https://infinispring.com/wp-content/uploads/2021/05/favicon.png</url>
	<title>FAILSAFE Archives - InfiniSpring</title>
	<link>https://infinispring.com/tag/failsafe/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>InfiniSpring® Overload Performance Testing &#8211; Tensile Tests</title>
		<link>https://infinispring.com/infinispring-overload-performance-testing/</link>
		
		<dc:creator><![CDATA[infinispring]]></dc:creator>
		<pubDate>Fri, 27 Sep 2024 08:42:47 +0000</pubDate>
				<category><![CDATA[Test]]></category>
		<category><![CDATA[ACOUSTICPRODUCTS]]></category>
		<category><![CDATA[FAILSAFE]]></category>
		<category><![CDATA[InfiniSpring]]></category>
		<category><![CDATA[PLASTICDEFORMATIONCAPACITY]]></category>
		<guid isPermaLink="false">https://infinispring.com/?p=1890</guid>

					<description><![CDATA[<p>We have done several tests for the InfiniSpring® Acoustic Products during last year. For the acoustic hanger products integrated fail-safe system was validated. Below video shows the fail-safe system in action for the acoustic hanger AH60N. Acoustic hanger load is shown in kilograms in the video. Final failure occurs for the GK-1 PN steel profile,&#8230;</p>
<p><a class="more-link" href="https://infinispring.com/infinispring-overload-performance-testing/" title="Continue reading &#8216;InfiniSpring® Overload Performance Testing &#8211; Tensile Tests&#8217;">Continue reading <span class="meta-nav">&#8594;</span></a></p>
<p>The post <a href="https://infinispring.com/infinispring-overload-performance-testing/">InfiniSpring® Overload Performance Testing &#8211; Tensile Tests</a> appeared first on <a href="https://infinispring.com">InfiniSpring</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>We have done several tests for the InfiniSpring® Acoustic Products during last year. For the acoustic hanger products integrated fail-safe system was validated. Below video shows the fail-safe system in action for the acoustic hanger AH60N. Acoustic hanger load is shown in kilograms in the video. Final failure occurs for the GK-1 PN steel profile, from which the hanger shears through at 300 kg load. Tested acoustic hanger is for static loads up to 25 kg and the ceiling system failure occurs on a load level of 300 kg (12 x nominal load) giving very high safety margin for the acoustic hangers.</p>
<p><iframe title="YouTube video player" src="https://www.youtube.com/embed/bWMhb8SzZ5k?si=Pb3aEKi4ZUZiFjla" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>Similar tests have been also completed for acoustic wall ties. Acoustic wall ties are not equipped with a fail-safe system and the video below shows the final failure mechanism for an Acoustic Wall Tie AWT94NA. The test revealed that InfiniSpring®-spring has extremely large plastic deformation capacity. The spring stretches similarly as a chewing gum and it has a new shape after the test. The spring does not fail, and the final failure occurs as the acoustic wall tie riveted joint failed on a load level of 210 kg (8 x nominal load).</p>
<p><iframe title="YouTube video player" src="https://www.youtube.com/embed/WgG0eIE8D7M?si=abo3qb9YDmMuJ55V" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>These highly positive test results for the acoustic products have made us to test InfiniSpring®-springs even more. We have now more recently tested overload and shock load capacity for the springs. We will present these test results also shortly.</p>
<p>&nbsp;</p>
<p>The post <a href="https://infinispring.com/infinispring-overload-performance-testing/">InfiniSpring® Overload Performance Testing &#8211; Tensile Tests</a> appeared first on <a href="https://infinispring.com">InfiniSpring</a>.</p>